External Wall

Maytech’s external wall systems: Designed for cleanrooms, cold rooms, and specialized storage environments, providing exceptional insulation, moisture control, and long-term reliability in critical applications.
Technical Data of Rockwool Panel
Types Horizontal Type (Non-Progressive)
Panel Width 1000mm
Core Density Density 100kg/m³
Panel Thickness 50mm / 75mm / 100mm
Panel Length Maximum 9000mm
Joint Hidden Fix
Surface Materials Small Wave / Corrugated / Flat
Outer Facing Materials AL-ZN-MG
Thickness: 0.6mm
Color: White / 20um
Content: AZM150 /g
Inner Facing Materials AL-ZN
Thickness: 0.4mm
Color: White / 20um
Content: AZ150 /g
Thermal Conductivity 0.36-0.040 w/mK
Compressive Strength >40 KPA
Sirim Certificate BS476: PART 6:1989 + A1 2009, BS476 PART 7:1997
Fire Rated Certificate Bomba Class "O"

This system offers a 9-meter-long Rockwool external wall panel with key features that include concealed screw installation, a modern aesthetic appeal, rapid installation, impressive wind resistance, effective waterproofing, and enhanced sound and thermal insulation

Non-combustible material testing
1. BS 476: Part 4 (Non-combustibility test for materials)
 
For building height < 18meter
  1. BS 476: PART 6 (Method of Test for Fire Propagation for Products)
  2. BS 476: PART 7 (Method for Classification of the Surface Spread of Flame of Products)
For building height > 18m (measured from the level of the fire apparatus, must use non-flammable materials)
  1. BS 8414- 1 (Fire Performance of external cladding systems. Test method for non-loadbearing external cladding systems applied to the masonry face of a building
  2. BS 8414-2 (Fire performance of external cladding systems. Test method for non-loadbearing external cladding systems fixed to and supported by a structural steel frame

Overview

BS 8414 STANDARD 
Purpose: The test intended to represent the action of a fire contact on the external surfaces of the cladding system

Does not cover:
1. Exposure to radiant heat from a fire in an adjacent building
2. Does not assess the fire resistance characteristics of the system

Performance Criteria PART 1 PART 2
External Fire Spread Considered Failed: If temperature rise above Ts of any of the external thermocouples at level 2 exceeds 600°C for a period of at least 30s, within 15 mins of start time, ts.
Internal Fire Spread Considered Failed: If visible flaming which exceeds the confines of the test vertically/ sideways during the full 1 hr testing period for more than 60s.
Mechanical Performance Considered Failed: If there is any collapse of the system/parts (At least 500mm length & 200 gm) onto the floor within the full 1 hr testing period.
Burning Debris & Pool Fires Considered Failed: If burning debris/ fire pool develops on the floor of test facility during full 1 hr testing period.
Additional requirement Considered Failed: Where fire reaches the internal surface, with duration in excess of 60s on the test specimen at height: 0.5m above combustion chamber opening within 15 mins of start time, ts.
Field of Application (thickness, density, cavity depths) The thinnest and thickest insulation for a given system type, where other specifications remained unchanged shall be tested. If only ONE thickness tested, the BOMBA approval will be limited to that.